The device is a signal tracking transducer. Its output quickly vary with input signal. It works on high-linearity analog optocoupler principle. It can convert AC/DC current/voltage input signal to electrically isolated, standard AC/DC current/voltage signal. Its input, outputs and power supply are electrically isolated from each other. The signal tracking transducer features high accuracy, high isolation, wide frequency band, fast response, low distortion, low drift and wide range of operation temperature. It can filter the common-mode noise generated during the transmission of signals from sensors, transducers or instruments and make a very good isolation and standardization of the signal. The transducer is particularly suitable for acquisition of high-speed transient waveform, harmonic analysis and fast testing and alarm systems. It can be applied widely to various measuring and controlling systems such as communication system, electrical power system, railway and various industrial control systems.

Part numbers

Input

Output

Part number

Current

DC

Current

0 ~ 5V dc

CE-IZ05-34MS

0~ 20mA dc

CE-IZ05-44MS

4~ 20mA dc

CE-IZ05-54MS

0~ 10V dc

CE-IZ05-84MS

AC

Current

4~ 20mA ac

CE-IJ05-34MS

0~ 20mA ac

CE-IJ05-44MS

Bidirectional DC Current

0~ ±5V dc

CE-IB05-34MS

0~ ±20mA dc

CE-IB05-44MS

0~ ±10V dc

CE-IB05-84MS

Voltage

DC

Voltage

0~ 5V dc

CE-VZ05-34MS

0~ 20mA dc

CE-VZ05-44MS

4~ 20mA dc

CE-VZ05-54MS

0~ 10V dc

CE-VZ05-84MS

AC

Voltage

4~ 20mA ac

CE-VJ05-34MS

0~ 20mA ac

CE-VJ05-44MS

Bidirectional DC Voltage

0~ ±5V dc

CE-VB05-34MS

0~ ±20mA dc

CE-VB05-44MS

0~ ±10V dc

CE-VB05-84MS

Specifications

  • Case Style: S1, no aperture
  • Input: Current :0-1mA ~ 5A, Voltage: 0-50mV ~ 1000V
  • Output: (bidirectional) AC/DC current/voltage (isolated)
  • Load capability:
    Current output:£500W, Voltage output: 5mA
  • Accuracy: 0.2%
  • Temperature drift: 250ppm/ oC
  • Overload: 2 times of full span (1 second, 10 times)
  • Response time: 20µS
  • 3 db Frequency band: 30kHz
  • Isolation voltage: >2500V DC/1 minute
  • Power supply: +24V±10%
  • Power consumption:1W
  • Operating temperature: 0-50 oC

Connections


Fig. 1. Connections of signal tracking transducer

Terminal 1: IN+, Positive V/I input
Terminal 3: IN-, Negative V/I input
Terminal 5: +24V, Power supply
Terminal 6: GND, Negative power supply
Terminal 8: Vg/Ig-, Negative Output
Terminal 9: Vg/Ig+, Positive Output
Don’t use all terminals named NC.

Case style and Mounting diagram(mm)
S1 case style is shown in Fig.2. Dimensions: L x W x H: 36 x 83 x 76 mm. Type 35 DIN rail mounting or screw mounting shown in Fig.3. The spacing between terminals is 5.08 mm.


Fig.2 Case style S1 Fig. 3. DIN rail or screw mounting

Notes

  1. Please check the part numbers, number of products according to the packing list and labels on the products carefully before use.
  2. Please shield the input of the transducer for anti-interference, or, as a result of the fast response of the transducer, the noise carried by input signal may affect the output.
  3. Please make sure to connect input, output and power supply correctly in accordance with the connection diagram of your part number before power on.
  4. Conductive dust and corroding gases may damage the circuit and connections. They are hazardous to the product. Don’t operate in that environment.
  5. Please ensure the terminal screws are tightened securely and reliably before measuring with probes of meters directly on the terminals.
  6. If more than one transducers are mounted together, keep a space more than 10mm between adjacent units.
  7. The transducer has been calibrated before delivery. Please contact the company if readjustment is required.
  8. Don’t disassemble the standard signal isolator. Please avoid impact or falling down from a high place. Do not remove or damage the labels on the product.
  9. Please take additional and reasonable means for lightning protection, especially when the input and output wires of the transducer are exposed outdoor.

2004 © Copyright by Shenzhen Sensor Electronic Technology Co.,Ltd.
Address: unit 4-2; Floor 4; Shenzheng Building; 42 MeiLin Road; Shenzhen City; China
E-mail:sales@ce-transducer.com tech@ce-transducer.com
Tel: 0086 755 8376 6915 Fax: 0086 755 8376 3161
GuangDong,China ICP NO:05081717