Single phase AC current transducer

HOME > PRODUCT > Transducers used in railway

  • ​ENTRIES:Part Number GuideData SheetFAQ
  • This device is a 1-phase AC current transducer. The input and output are not common ground, the input signal is AC current, the output signal is 0-5V. The product has good accuracy, high isolation voltage, low temperature drift, small size, easy installation, etc., in line with international standards. It can be widely used in telecommunications, electricity, railways, industrial control and other fields.


    Data Sheet

    Test conditions: power supply: +12V DC, room temperature:25℃

    Input range: 0~30A AC

    Frequency range: 1700Hz~2600 Hz

    Output: 0-5V DC

    Power supply: 12VDC  

    Accuracy:  0.5 class    

    Load capacity: load ≥2KΩ

    Temperature drift: ≤250ppm/

    Operating temperature:  0~50

    Isolation voltage: ≥2500 V DC  

    Response time: ≤300 mS                

    Rated power consumption: ≤30mW  

    Output ripple: ≤10mV

    Frequency range: 45~65Hz (up to 5K, please specify when ordering)

    Input overload capacity: 20 times the value of the measured current (Maximum 500A) (one second repeat 5 times, interval 300S)

    Surge impact immunity:

    Power port level ±0.5KV (L-N/2Ω/ integrated wave)

    Analog I/O port level±0.5KV (L-N/40Ωintegrated wave)

    Impulse immunity: input / power port ±2KV, Analog I /O port±1KV

    Operating temperature: 0~50; humidity: ≤95%( no dew)

    Storage temperature:-55~65; humidity: ≤95%no dew


     64346F20B51B4C31A3ACDEC893D1005D.jpg



    32CCEB06A8794D86AB70B1AC80600743.jpg

                                                                             Outline drawing of CE-IJ03-32CD

    BAA6805E2439493CB8A551BEFA68242C.jpg                                                                   

                                                                                                                           Dimension drawing of CD case style

    0DC134C95CF646A9BFF10A790690DBBC.png

                                                               Wiring diagram of CE-IJ03-32CD with voltage output

    High accuracy, more than 0.5.

    Low temperature drift, not exceed the accuracy range, and stability;

    High Isolation voltage, small size, easy installation and so on;


    Related Products