DC Voltage Transducer
Test conditions: auxiliary power supply: +12V, room temperature: 25℃.
Input range: 0~0.1V~300VDC;
Output: 0~5VDC, 0~10VDC, 0~20mADC, 4-20mADC,frequency(0~5KHz、0~10KHz);
Auxiliary power supply: 12VDC, 15VDC, 24VDC optional;
Accuracy: class 0.2;
Load capacity: Load ≥2KΩ (voltage output), load≤250Ω(current output);
Temperature drift: class 0.2 = 200ppm/℃ ;
Isolation voltage: 2500 V DC;
Response time: ≤15 mS;
Rated power consumption: voltage output≤400mW, current output≤800mW;
Output ripple: ≤10mV;
Surge impact immunity:
Power port three–level ±0.5KV(L-N/2Ω/ integrated wave),
Analog I /O port three-level ±0.5KV (L-N/40Ω/integrated wave);
Pulse group immunity: Input / power port ± 2KV Analog I / O port ± 1KV;
Input overload capacity: 2 times rated input value;
Operating condition: temperature: -10~60℃;
Storage condition: -40~+70℃.