Standard Signal Isolator

HOME > Current > Standard Signal Isolator

Test conditions: auxiliary power: +24 V, room temperature: 25 ℃;

Input range: 0-20mA/4-20mA/0-5A/0-10V/1-10V/0-500V or

Custom Input Type (Voltage Max 500V, Current Max 5A)

Output: 0-5V, 1-5V, 0-10V, 2.5±2.5V, 0-20mA, 4-20mA, 10±10mA;

Power supply: +24VDC (-15%~+20%)  

Accuracy:  0.2 class;      

Load capacity: current output ≤500Ω; voltage output ≥1kΩ;

Temperature drift: ≤100ppm/℃;

Isolation voltage: 2500VDC;  

Response time: ≤200 mS;                

Rated power consumption: <3W;

Output ripple: ≤10mV;

Frequency response range: none;

Surge immunity:

Power port two ±1KV (L-N/2Ω/ integrated wave) 

Output port three ±2KV (L-N/40Ω/integrated wav);

Impulse immunity:

input/power port ± 2KV, analog I/O port ± 1KV;

Input overload capacity:

2 times nominal value for the measured (apply a second, repeat 10 times, interval 10S);

Weight: 144g, size::L*W*H = 115*96*18mm

Operating temperature: 20~70℃; humidity: ≤95% (no dew)

Storage temperature: -40~+70℃.


Copyright© 2019 SHENZHEN SENSOR ELECTRONIC TECHNOLOGY CO., LTD粤ICP备05079934号-9