DC Multi-parameter Digital Transducer

HOME > Multi-parameter > DC Multi-parameter Digital Transducer

NO.

Item

Date

Unite

Remarks

1

Accuracy

1.0

%


Input range

1000V*1000A;



2

Baud rate

19.2K9600(default),   4800, 2400, 1200

bps

Factory default communication format:   9600, N / 8/1, address 1

Communication

RS-485(twisted pair line) , RS-232C(treble   line, only for N style parts)


RS422 optional

Parity

None, Even, Odd, Space



Max. number of nodes

64

node

Only for RS-485

Bus protection

400W transient voltage


ESD protection and thermosnap

3

A/D SPEED

100

mS


4

Working temperature

-20~+60



5

Isolation voltage

Input/output:   2500V DC for 1 min

Input/power supply2500V   for 1 min

Output/power supply2500V   for 1 min

 

V

 

The double isolation part numbers, their   output and power supply are grounded together , there is only between the input and output   isolation voltage

6

Overload

2 x voltage span 1   sec. 10 for times with interval of 10 sec.

10 x current span   for 1 sec. 5 times with an interval of 300 sec (only for hole thru. parts)


The input outside the linear range will   result in poor accuracy

7

MTBF

>30000

hour


8

Auxiliary power supply

+5V/+12V/+24V/+48V/ AC220V

V

220VAC,DC only for N case parts

9

Power consumption

≤250mW(+12V)≤500mW(+24V)

mW

Power consumption depends on power supply   to be used

10

Temperature drift

≤300

ppm/

 (-20℃~+60℃)


Copyright© 2019 SHENZHEN SENSOR ELECTRONIC TECHNOLOGY CO., LTD粤ICP备05079934号-9