DC multi-parameter digital transducer

HOME > Multi-parameter > DC Multi-parameter Digital Transducer

  • ​ENTRIES:Part Number GuideData SheetFAQ
  • This product is a 1-phase DC power acquisition measurement intelligent isolation transducer. It can measure the current, voltage, power and electrical of the DC circuit. Using high-precision 24-bit dedicated AD chip, the ratio dynamic range can be up to 1000: 1. Hall measurement principle or resistance sampling measurement principle is with high accuracy, good stability and high communication speed, the completely isolated processing technology is with anti-interference ability. Measurement of electricity parameters through the RS-485 digital interface output to achieve long-distance transmission, the product MODBUS protocol is complete compatible with a variety of configuration software or PLC equipment MODBUS (RTU) protocol. It can be applied to power, room monitoring, industrial measurement and other fields.


    Data Sheet


    Serial number

    Item

    Date

    Unite

    Remarks

    1

    Accuracy

    0.51.0

    %

    Terminal input is 0.5, hole-thru. input is   1.0

    Input range

    MS3 case:500V*5A;

    ES5 case:1000V*1000A;

    MS5 case:1000V*5A;


    The maximum range for each specification

    2

    Baud rate

    115.2K, 57.6K, 38.4K, 19.2K, 9600(default)   4800, 2400, 1200

    bps

    Factory default communication format:   9600, N / 8/1, address 1; S5 type up to 19.2K;

    Communication

    RS-485(twisted pair line) , RS-232C(treble   line, only for N style parts)


    RS422 optional

    Parity

    None, Even, Odd, Space



    Max. number of nodes

    64

    node

    Only for RS-485

    Bus protection

    400W transient voltage


    ESD protection and thermosnap

    3

    A/D SPEED

    100

    mS


    4

    Working temperature

    -20~+60



    5

    Isolation voltage

    Input/output:   2500V DC for 1 min

    Input/power supply2500V   for 1 min

    Output/power supply2500V   for 1 min

     

    V

     

    The double isolation part numbers, their   output and power supply are grounded together , there is only between the input and output   isolation voltage

    6

    Overload

    2 x voltage span 1   sec. 10 for times with interval of 10 sec.

    10 x current span   for 1 sec. 5 times with an interval of 300 sec (only for hole thru.   parts) 


    The input outside the linear range will   result in poor accuracy

    7

    MTBF

    >30000

    hour


    8

    Auxiliary power supply

    +5V/+12V/+24V/+48V/ AC220V

    V

     220VAC,DC only for N case parts

    9

    Power consumption

    ≤250mW(+12V)≤500mW(+24V)

    mW

    Power consumption depends on power supply   to be used

    10

    Temperature drift

    ≤300

    ppm/

     (-20~+60)

    blob.png


    图片1.png

    CE-AD11-**MS3 Case Type

    16.png

    CE-AD11-**MS3 Installation Diagram

    CE-AD11-**ES5 Case Type 

    18.jpg

    CE-AD11-**ES5 Installation Diagram


                                                                                   CE-AD11-**MS5 Case Type

    18.jpg

    CE-AD11-**MS5 Installation Diagram


    Terminal definition and connection diagrams

    Connection diagram shown in figure 6.1 (Note: 3and 4 terminal for the common ground)

                                    

    242.jpg

      

                            Wiring diagram of CE-AD11-**MS3 product (Note the current access direction).

                              (Terminal 7 output is +5 V to provide 5V output (<20mA), the output and power are grounded together).

      

    When the S3 case DC current is greater than 5A, external shunt input wiring diagram is shown in Figure 6.2; (Note terminal 3 and 4 for the common ground).

    242.jpg

      

    Wiring diagram of CE-AD11 - ** MS3 product (external shunt input for currents greater than 5A).


    Refer to figure 6.3 for the wiring diagram of the S5 case. Current hole-thru input is maximum 1000A, when the current input from the terminal 5 and 6, the current should be ≤ 5A.


    图片8.png

    Wiring diagram of CE-AD11-**ES5

    ²  Available with wide power supply: DC: 10-30V or 10-55V or AC / DC: 85-265V.

    ² With odd parity, even parity, no parity, 2 stop bits and other communication methods are free to set.

    ² Communication speed optional, the maximum communication speed to 115200 bps.

    ²  The intelligent transducer with the smallest size and wide current measurement range in the peer.

    ² Electroplating has a positive and negative cumulative, and power-down storage function.

    ² With red and green light-emitting diode instructions function, the red light indicates the normal operation of the product (100mS flashing), the green light indicates the product communication.

    ²  High anti-interference ability, the input, output and power port to resist the surge voltage up to 2KV or more.


    Related Products