AC Multi-parameter Digital Transducer

HOME > Multi-parameter > AC Multi-parameter Digital Transducer

NO,

Item

Date

Unite

Remarks

1

Accuracy

0.2,0.5

%

0.2 for voltage and current value only

Input range

S3 case:500V*30A;  

S5 case:500V*200A; N1 case:500V*5A;


The maximum range for each specification

Frequency

Frequency response: 20Hz-1KHz; Frequency   measurement: 20-600Hz



2

Baud rate

RS-485(twisted pair line) , RS-232C(treble   line, only for N style parts)

bps

Factory default communication format:   9600, N/8/1, address 1; S5 type up to 19.2K;

Communication

None, Even, Odd, Space


RS422 optional

Parity

64



Max. number of nodes

400W transient voltage

Node

Only for RS-485

Bus protection

RS-485(twisted pair line) , RS-232C(treble   line, only for N style parts)


ESD protection and thermosnap

3

A/D SPEED

100

mS


4

Working temperature

-20~+60



5

Isolation voltage

Input/output:   2500V DC for 1 min

Input/power supply2500V   for 1 min

Output/power supply2500V   for 1 min

 

V

 

The double isolation part numbers, their   output and power supply are grounded together, there is only between the input and output   isolation voltage

6

Overload

2 x voltage span 1   sec. 10 for times with interval of 10 sec.

10 x current span   for 1 sec. 5 times with an interval of 300 sec (only for hole thru.   parts) 


The input outside the linear range will   result in poor accuracy

7

MTBF

>30000

Hour


8

Auxiliary power supply

+5V/+12V/+24V/+48V/ AC220V

V

220VAC,DC only for N case parts

9

Power consumption

250mW(+12V),≤500mW(+24V)

mW

Power consumption depends on power supply   to be used

10

Temperature drift

300

ppm/

 (-20~+60)