| Product: 1 Element DC Hall Effect
Analog Current Transducer
Series: CE-IZ04-D Case Style D
Input Range: 0-300A ~ 0-500A
Output: 100mA~200mA
Power Source:±12 V / ±15V
Accuracy: 1.0%
1 .List of Options
| SERIES |
OUTPUT |
POWER SOURCE |
WINDOW(mm) |
CASE STYLE |
INPUT RANGE |
| CE-IZ04-D |
2:0-200mA |
5:±12V
6:±15V |
F20 |
D2 |
0-400A |
| 2:150mA |
F20.5 |
D6 |
0-300A |
| 2:100mA |
F36 |
D7 |
0-500A |
2.Specifications
| LINEARITY RANGE |
1.5 times of the maximum of measuring range |
RESPONSE TIME |
1uS |
| OVERLOAD CAPABILITY |
2 times of the maximum of measuring range |
CURRENT CONSUMPTION |
£25ma + output current
|
| ACCURACY |
0.5% |
ISOLATION |
3KVRMS/50Hz/min |
| OFFSET CURRENT |
±0.2mA |
OPERATING TEMPERATURE RANGE |
-10°C~+80°C |
| HYSTERESIS ERROR |
±0.2mA |
STORAGE TEMPERATURE RANGE |
-25°C~85°C |
| TEMPERATURE DRIFT |
£200ppm/°C |
FIRE RETARDANCY |
UL94-V0 |
3. Connection:
The current carrying cable must pass through the window.
The phase of output is the same as that of the current passing
the window in the direction of the arrow indicated on the
case.
Wiring of Terminals for case style D2:
+: +15V/+12V Power Supply
M : Output
-: -15V/-12V Power Supply
Wiring of Terminals for case style D6, D7:
1. +15V/+12V Power Supply
2. -15V/-12V Power Supply
3. +Output
4. NC
4. Cases of series D
Type D2:

Type D6:

Type D7:

Application Characteristic: Can be used for measuring
DC, AC, pulsed currents, etc. The output of the transducer
reflects the real wave of the current carrying conductor.
Characteristic of Products: Small size, light in weight,
less power consumption, window structure, electrically isolating
the output of the transducer from the current carrying conductor,
no insertion loss.
Application: Frequency conversion timing equipment,
various POWER SOURCE, UPS, electric welding machine, transformer
substation, numerical control machine tool, electrolyzing
equipment, electroplating equipment, electric powered locomotive,
microcomputer monitoring, electric power net monitoring.
Notes:
1. Connect the terminals of POWER SOURCE, outputs respectively
and correctly, never make wrong connection.
2. Two potentiometers can be adjusted, only if necessary,
by turning slowly to the required accuracy with a small screwdriver.
3. The best accuracy can be achieved when the window is fully
filled with bus-bar (current carrying conductor).
4. The in-phase output can be obtained when the direction
of current of current carrying conductor is the same as the
direction of arrow marked on the transducer. |