Home > Product > CE-H Series list > CE-IZ04-A  

CE-IZ04-A

Email Print Chart Catalog
 

Product: 1 Element DC Hall Effect Analog Current Transducer
Series: CE-IZ04-A Case Style A
Input Range: 30-500A ~ 100-800A
Output: 0-4V / 0-5V / 0-20mA / 4-20mA
Power Source: ±12 V / ±15V
Accuracy: 1.0%


1. List of Options

SERIES
OUTPUT
POWER SOURCE
WINDOW(mm)
CASE STYLE
INPUT RANGE
CE-IZ04-A

9:0-4V
3:0-5V

5:±12V
6:±15V

20*10
A1
0-50~600A
F23
A2
0-30~500A
21*10
A3
0-50~600A
9:0-4V; 3:0-5V
4:0-20mA; 5:4-20mA
33*16
A4
100~800A
33*11
A5
100~500A

9:0-4V
3:0-5V

F16
A6
0-50~400A
F20.4
A8
100~400A

2 .Specifications

LINEARITY RANGE 1.5 times of the maximum of measuring range RESPONSE TIME 10uS
OVERLOAD CAPABILITY 20 times of the maximum of measuring range CURRENT CONSUMPTION £25mA
ACCURACY 1% ISOLATION 3KVRMS/50Hz/min
OFFSET VOLTAGE ±25mV OPERATING TEMPERATURE RANGE -10°C~+80°C
HYSTERESIS ERROR ±10mV STORAGE TEMPERATURE RANGE -25°C~85°C
TEMPERATURE DRIFT £250ppm/°C FIRE RETARDANCY UL94-V0

3. Connection:
The current carrying cable must pass through the window. The phase of output is the same as that of the current passing the window in the direction of the arrow indicated on the case.

Wiring of Terminals for case style A1, A2, A3, A4, A5, A6, A7, A8 :
1. +15V/+12V Power Source
2. -15V/-12V Power Source
3. Output
4. Ground
5. NC (only A6)



4 .Cases of series A

Type A1:

Type A2:

Type A3:

Type A4:

Type A5:

Type A6:


Type A7
:

Type A8:


Application Characteristic:
Can be used for measuring DC, AC, pulsed currents, etc. The output of the transducer reflects the real wave of the current carrying conductor.
Characteristic of Products: Small size, light in weight, less power consumption, window structure, electrically isolating the output of the transducer from the current carrying conductor, no insertion loss.
Application: Frequency conversion timing equipment, various POWER SOURCE, UPS, electric welding machine, transformer substation, numerical control machine tool, electrolyzing equipment, electroplating equipment, electric powered locomotive, microcomputer monitoring, electric power net monitoring.

Notes:
1. Connect the terminals of POWER SOURCE, outputs respectively and correctly, never make wrong connection.
2. Two potentiometers can be adjusted, only if necessary, by turning slowly to the required accuracy with a small screwdriver.
3. The best accuracy can be achieved when the window is fully filled with bus-bar (current carrying conductor).
4. The in-phase output can be obtained when the direction of current of current carrying conductor is the same as the direction of arrow marked on the transducer.

     
Selection Guide Ordering Instructions Notice to user
2004 © Copyright by Shenzhen Sensor Electronic Technology Co.,Ltd.
Address: unit 4-2; Floor 4; Shenzheng Building; 42 MeiLin Road; Shenzhen City; China
E-mail:sales@ce-transducer.com tech@ce-transducer.com
Tel: 0086 755 8376 6915 Fax: 0086 755 8376 3161
GuangDong,China ICP NO:05081717