Main Series Guide for CE-A Digital Electrical Transducer

PRODUCT DESCRIPTION SERIES MEASURING RANGE

3-Phase Cross-functional Electrical Transducer
3-phase 4-wire;Output: analog,RS485 and /or relay/pulse

AJ42 Current:0~5A
Voltage:0~500V
4 switching value inputs

Multi-parameter Digital Transducer
1 Element AC RMS
Output:RS485 or RS232C

AJ12 Current:0~25A
Voltage:0~500V
Multi-parameter Digital Transducer
3-phase 3-wire AC RMS
Output:RS485 or RS232C
AJ32 Current:1~25A
Voltage:0~500V
Multi-parameter Digital Transducer
3-phase 4-wire AC RMS
Output:RS485 or RS232C
AJ42 Current:1~25A
Voltage:0~500V
Multi-parameter Digital Transducer
1 Element AC RMS
Output: RS485 or RS232C, with accumulative energy data power failure protection function
AJ12B Current:1~25A
Voltage:0~500V
Multi-parameter Digital Transducer
3-phase 3-wire AC RMS
Output: RS485 or RS232C, with accumulative energy data power failure protection function
AJ32B Current:1~25A
Voltage:0~500V
Multi-parameter Digital Transducer
3-phase 4-wire AC RMS
Output: RS485 or RS232C, with accumulative energy data power failure protection function
AJ42B Current:1~25A
Voltage:0~500V
Current Digital Transducer
1 Element AC RMS
Output:RS485 or RS232C
AI12 Current:1~25A
Current Digital Transducer
3 Elements AC RMS
Output:RS485 or RS232C
AI32

Current:1~25A

Current Digital Transducer
1 Element DC
Output:RS485 or RS232C
AZ11 Current:1~25A
0~±20mA
0~±200mA
Voltage Digital Transducer
1 Element AC true RMS
Output:RS485 or RS232C
AV12 Voltage:0~500V
Voltage Digital Transducer
3-phase 3-wire AC true RMS
Output:RS485 or RS232C
AV32 Voltage:0~500V
Voltage Digital Transducer
3-phase 4-wire AC true RMS
Output:RS485 or RS232C
AV42 Voltage:0~500V
Voltage Digital Transducer
1 Element DC
Output:RS485 or RS232C
AU11

Voltage:0~500V
75mV

Note: Some of Transducer are double isolated. It means that the output of the transducer is electrically isolated from its input. Some of Transducer are treble isolated. It means that the input, output and power source of the transducer are isolated each from others.
       
Selection Guides System Connecting Application and Programming Instructions of CE-485A(RS-485/RS-232C) Converter
2004 © Copyright by Shenzhen Sensor Electronic Technology Co.,Ltd.
Address: unit 4-2; Floor 4; Shenzheng Building; 42 MeiLin Road; Shenzhen City; China
E-mail:sales@ce-transducer.com tech@ce-transducer.com
Tel: 0086 755 8376 6915 Fax: 0086 755 8376 3161
GuangDong,China ICP NO:05081717