| Home >
Product > CE-T Series list > CE-IJ03-J |
|
CE-IJ03-J,VJ03-J,IZ04-J,VZ01-J |
|
| PRODUCT: |
AC Offside Alarm Transducer |
| SERIES: |
CE-IJ03-J (AC 1A~300A) |
|
CE-VJ03-J (AC 0-75mV~1000V) |
| PRODUCT: |
DC Offside Alarm Transducer |
| SERIES: |
CE-IZ04-J (DC 1A~300A) |
|
CE-VZ01-J (DC 0-75mV~1000V) |
| INPUT RANGE: |
0-75mV~1000V, 1A~300A |
| RETURN INPUT: |
-5~50 |
| OUTPUT: |
Relay Contacts |
| ACCURACY: |
2.0% |
| RESPONSE TIME: |
£300ms |
| POWER SOURCE: |
+24V |
| LOAD CAPABILITY: |
Voltage Output³2kW |
|
|
Current Output£250W |
| QUISCENT POWER CONSUMPTION: |
£600mw |
Specifications:
Other
Typical Specifications
| Item |
Test condition |
Index |
| Class 0.2 |
Class 0.5 |
Thermal Drift |
+12V, 25°C |
£200ppm/°C |
£500ppm/°C |
| Output Ripple |
+12V, 25°C |
10mV |
15mV |
| Output Load |
+12V, 25°C
Vz (3) output
|
³2kW |
+12V, 25°C
Iz (4) and Iy (5) output
|
£250W |
| Operating Temperature |
+12V |
0~50°C |
| Isolation Withstanding
Voltage |
1 min. |
£2500vdc |
| 1 min. |
£1500
Vac RMS |
|
| |
| Series |
Operating Principle |
Isolation Voltage |
Input Frequency Range |
Response Time Range 0~90%
FS |
Overload Capacity |
Quiescent Power** (mW) |
Mounting |
| CE-VJ03-J |
Electromagnetic |
£2500VDC |
25~3kHz |
<200 |
5 Times 5/sec ,relay contacts current: £2a
DC/AC |
<600 |
Din Rail |
| CE-VZ01-J |
Treble Isolation* |
DC |
<50 |
<600 |
Din Rail |
| CE-IJ03-J |
Electromagnetic |
25~3kHz |
<200 |
<600 |
Din Rail |
| CE-IZ04-J |
Hall Effect |
DC |
<300 |
<600 |
Din Rail |
Three Isolation: Isolations among input of transducer, output of transducer
and power source.
** Quiescent power: with power source 24V List of options: Remark
| Series |
Output |
Power Source DC |
Window opening
(mm) |
Case Style |
Accuracy |
threshold Value input |
Return input |
| Voltage
/ current |
% |
| CE-VJ03-J |
J:Relay Output |
4---24V |
M:No Window |
S3 |
2.0 |
75mV,10V,50V,100V,
250V,500V,1000V |
-5,-10,
-15,-30
-40,-50 |
| CE-VZ01-J |
J:Relay Output |
4---24V |
M:No Window |
S3 |
2.0 |
75mV,10V,50V,100V,
250V,500V,1000V |
| CE-IJ03-J |
J:Relay Output |
4---24V |
A: F4
B: F6.5
D: F13
E: F20
|
S3 |
2.0 |
1A,10A,30A,50A,75A,
100A,150A,200A,250A,
300A |
| CE-IZ04-J |
J:Relay Output |
4---24V |
A: F4
B: F6.5
D: F13
E: F20
|
S3 |
2.0 |
10A,30A,50A,75A,100A,
150A,200A,250A,300A |
Part Number Example: CE-IJ03-J4DS3/2.0*75A*-30
Description: AC Offside Alarm Transducer, Relay contacts output,
Power source:24V, window: F13mm, Case
style:S3, Accuracy: 2.0%, Threshold Value: 75A, Return Input: -30%
Diagrams: (Click one of small diagrams to magnify it in the
right rectangle)
| Case Style |
Installation |
Connection |
| |
|
|
| |
|
|
|
 |
Application:
- Harmonic voltages
- Chopped waveform drivers
- Quickly varying voltage supplies
- Phase fired controlled devices
Notice:
1. The load current of output should not exceed the maximal current
value, which relay contacts allow to pass.
2. 24V power supply should be stabilized within ±5%.
3. We can set threshold value and return value to meet your request
if the above value can't meet your request.
|