| Home >Product>
CE-T Series list > CE-IJ31 |
|
CE-IZ01,IZ02,IZ04,IZ06 |
|
| PRODUCT: |
1 Element DC Analog Current Transducer |
| SERIES: |
CE-IZ01 |
| |
CE-IZ02 |
| |
CE-IZ04 |
| |
CE-IZ06 |
| INPUT RANGE: |
20mA~300A |
| OUTPUT: |
5V or 4-20 mA or Two Channel Output(Vd+Id or Vd+Vd) |
| ACCURACY: |
0.2% or 0.5% or 1.0% |
| RESPONSE TIME: |
=100 mS |
| POWER SOURCE: |
+12V or +15V or +24V |
| LOAD CAPABILITY: |
Voltage Output³2kW |
|
|
Current Output£250W |
| QUISCENT POWER CONSUMPTION: |
=550mW |
Specifications:
Other
Typical Specifications
| Item |
Test condition |
Index |
| Class 0.2 |
Class 0.5 |
Thermal Drift |
+12V, 25°C |
£200ppm/°C |
£500ppm/°C |
| Output Ripple |
+12V, 25°C |
10mV |
15mV |
| Output Load |
+12V, 25°C
Vz (3) output
|
³2kW |
+12V, 25°C
Iz (4) and Iy (5) output
|
£250W |
| Operating Temperature |
+12V |
0~50°C |
| Isolation Withstanding Voltage |
1 min. |
£2500vdc |
| 1 min. |
£1500
Vac RMS |
| Series |
Operating
Principle |
Isolation
Voltage |
ResponseTime Range
0 to 90 % FS |
Overload
Capacity |
Quiescent Power(mW) |
Mounting |
| Vz,Vd,Vg,Iz
Output |
Iy Output |
| CE-IZ01 |
Photoelectrical
Induction
/Treble Isolation |
£2500VDC |
£10ms |
5 Times 5/sec |
180 |
300 |
PCB Surface
or
Din Rail
|
| CE-IZ02 |
Magnetic Modulation |
£15ms |
200 |
300 |
| CE-IZ04 |
Hall Effect |
£10ms |
350 |
550 |
| CE-IZ06 |
Magnetic Modulation |
£100ms |
600 |
700 |
List of options: Remark
1 Explain for Code
| Code |
3 |
4 |
5 |
6 |
8 |
F |
| Symbol |
Vz |
Iz |
Iy |
Vy |
Vd |
F |
| Definition |
DC Voltage Output
|
DC Current Output
|
DC Current Output
|
DC Voltage Output
|
DC Voltage Output
|
OC Frequency Signal
Output |
2 Explain for
* Loop resistance from 0 to 250W. Contact
factory for loop resistance
above 250 O
| Series |
Output |
Power Source |
Window (mm) |
Case Style |
Accuracy |
Input Range( RMS ) |
| CE-IZ01 |
3: 0~5VDC(Vz)
4: 0~20 mA(Iz)
5: 4~20 mA(Iy)*
6: 1~5VDC(Vy)
8: 0~10VDC(Vd)
F: Frequency signal
T:Two Channel Output(Vd+Id or Vd+Vd)
|
2: 12V
3: 15V
4:24V |
M: none |
S1 |
0.2
|
20mA,50mA,100mA,200mA |
| S3 |
500mA,1A,2A,5A |
| CE-IZ02 |
8: 110V
9:220V |
H2
S1 |
20mA,50mA |
| S2 |
100mA,200mA,500mA,1A,2A,5A |
| CE-IZ04 |
2: 12V
3: 15V
4: 24V
5: ±12V
6: ±15V |
E: F20 |
S3 |
1.0 |
30A,50A,80A,100A,
120A,150A,200A,300A |
| CE-IZ06 |
1A,2A,5A,10A,20A |
Part Number Example: CE-IZ01-32MS2-0.2/4~20mA
Description: 1element DC Current Transducer, average responding,
Input: 4~20mA,Output: 0~5Vdc, power source: +12Vdc, Window : none
(Terminal input), Accuracy: 0.2%, Case Style:S2
Diagrams:(Click one of small diagrams to magnify it in the
right rectangle)
| Case Style |
Installation |
Connection |
| |
|
|
| |
|
|
| |
|
|
| |
|
|
|
 |
Applications:
- POWER SOURCE management
- DC motor drives
- Battery chargers and systems
- Mobile applications.
Notice:
- If the input signal is bi-directional DC or pulse DC, please
make mention in your order.
- In case of the current (>1A) is terminal input, it is advisable
to connect 1&2, terminals in parallel and 3&4, terminals
in parallel in order to lower the input resistance at terminals.
- CE-IZ01 works on Three Isolation Principle, the output signal
and the power source may not be earthed in common. ( while that
of other part number must be earthed in common)
|