| Home >Product>
CE-IJ31 |
|
CE-IJ31,CE-IJ31A |
|
| PRODUCT: |
3 Elements AC Analog Current Transducer |
| SERIES: |
CE-IJ31 |
|
CE-IJ31A(TRUE RMS) |
| INPUT RANGE: |
0.5A~25A |
| OUTPUT: |
5V or 4-20 mA |
| ACCURACY: |
0.2% or 0.5% |
| RESPONSE TIME: |
£300ms |
| POWER SOURCE: |
+12V or +15V or +24Vor +220V |
| LOAD CAPABILITY: |
Voltage Output³2kW |
|
|
Current Output£250W |
| QUIESCENT POWER CONSUMPTION: |
=480mW |
Specifications: Other
Typical Specifications
| Item |
Test condition |
Index |
| Class 0.2 |
Class 0.5 |
Thermal Drift |
+12V, 25°C |
£200ppm/°C |
£500ppm/°C |
| Output Ripple |
+12V, 25°C |
10mV |
15mV |
| Output Load |
+12V, 25°C
Vz (3) output
|
³2kW |
+12V, 25°C
Iz (4) and Iy (5) output
|
£250W |
| Operating Temperature |
+12V |
0~50°C |
| Isolation Withstanding Voltage |
1 min. |
£2500vdc |
| 1 min. |
£1500
Vac RMS |
| Series |
Operating
Principle |
Isolation
Voltage |
ResponseTime Range
0 to 90% FS |
Overload
Capacity |
Quiescent Power(mW) |
Mountin |
| Vz,Vd,Vg,Iz
Output |
Iy Output |
CE-IJ31
CEIJ31A |
Electro-magnetic |
£2500VDC |
£300ms |
20 times or <5/sec at 500A |
300(accuracy 0.2)350
(accuracy 0.5) |
480(accuracy 0.2)
450(accuracy 0.5) |
Din Rail |
List of options: Remark
1 Explain for Code
| Code |
1 |
3 |
4 |
5 |
8 |
| Symbol |
Vg |
Vz |
Iz |
Iy |
Vd |
| Definition |
Tracing Voltage
Output |
DC Voltage Output
|
DC Current Output
|
DC Current Output
|
DC Voltage Output
|
2 Explain for
| Series |
Output |
Power
Source |
Window Opening(mm) |
Case Style |
Accuracy |
Input Range(RMS) |
CE-IJ31
CE-IJ31A |
1:0~5V RMS(Vg)
3:0~5V DC (Vz)
4:0~20mA (Iz)
5:4~20mA (Iy)
8:0~10V DC (Vd) |
2:12V
3:15V
4:24V |
B--F6.5 |
S3 |
0.5 |
1A,2A,5A,
10A,15A,25A |
CE-IJ31
CE-IJ31A |
3:0~5V DC (Vz)
4:-0~20mA (Iz)
5:4~20mA (Iy)
6:1~5V(Vy)
8---0~10V DC (Vd) |
8:110V
9:220V |
SK
SL |
1A,2A,5A,
10A,15A,20A |
*Tracking output(Vg,Iz,Vd) type not available in series CE-IJ31A
**Loop resistance from 0 to 250
W,Contact factory for loop resistance above 250 W
Part Number Example: CE-IJ31-32BS3-0.5/0~5A
Description: 3-phase AC Current Transducer, average responding, Input:
0-5Aac, Output: 0-5Vdc, Power Source: +12Vdc, Window: F6.5mm,
Case Style: S3 Accuracy: 0.5 %, Diagrams : (Click
one of small diagrams to magnify it in the right rectangle)
| Case Style |
Installation |
Connection |
|
|
|
|

|
| |
SL case style |
BSK case style |
Case |
 |
|
| Installation |
|
 |
|
 |
|
Application:
- To monitor electrical power system.
- To monitor 3-phase motor loads.
Notice:
- There is no polarity requirement for the input signal connection.
- For application above 25 Amp use an external current. Connect
the secondary leads of the current transformer to the input of
the Transducer.
- The output signal and the power source are common at pin 6.
|
|