| PRODUCT: |
1 ELEMENT AC CURRENT TRANSDUCER |
| SERIES: |
CE-IJ03 |
| |
CE-IJ03A (TRUE RMS) |
| INPUT RANGE: |
0.5A~300A |
| OUTPUT: |
5V or 4-20 mA |
| ACCURACY: |
0.2% or 0.5% |
| RESPONSE TIME: |
300 mS |
| POWER SOURCE: |
+12V or +15V or +24V |
| LOAD CAPABILITY: |
Voltage Output ³2kW |
|
|
Current Output£250W |
| QUISCENT POWER
CONSUMPTION: |
£ 300 mW
|
Specifications:
Other
Typical Specifications
| Item |
Test condition |
Index |
| Class 0.2 |
Class 0.5 |
Thermal Drift |
+12V, 25°C |
£200ppm/°C |
£500ppm/°C |
| Output Ripple |
+12V, 25°C |
10mV |
15mV |
| Output Load |
+12V, 25°C
Vz (3) output
|
³2kW |
+12V, 25°C
Iz (4) and Iy (5) output
|
£250W |
| Operating Temperature |
+12V |
0~50°C |
| Isolation Withstanding
Voltage |
1 min. |
£2500vdc |
| 1 min. |
£1500
Vac RMS |
|
| |
| SERIES |
OPERATING PRINCIPLE
|
ISOLATION VOLTAGE
|
RESPONSE TIME (ms)
|
OVERLOAD CAPABILITY
|
Quiescent Power(mW) |
MOUNTING |
| Vz,Vd,Vg,Iz Output |
Iy Output |
| CE-IJ03 |
|
£2500VDC |
£400ms |
The minor of 20 times or 500A 5/sec |
180 (0.2% accuracy) |
300 (0.2%) |
DIN Rail
or PCB
|
| CE-IJ03A |
200(0.5% accuracy) |
250(0.5%) |
List of options: Remark
| Series |
Output |
Power Source |
Window (mm) |
Case Style |
Accuracy
% |
Rated Input |
| CE-IJ03 |
3: 0~5V DC(Vz)
|
2:12V |
B--F6.5 |
H1 |
0.5
|
0.5A,1A,5A,10A,15A,25A |
CE-IJ03
CE-IJ03A
|
1: 0~5V RMS(Vg)
3: 0~5V DC(Vz)
4: 0~20 mA(Iz)
5: 4~20 mA(Iy)
6: 1~5V dc(Vy)
7: 4~20 mA(Id)
8: 0~10V DC(Vd)* |
2---12V
3---15V
4---24V
5---±12V
6---±15V
|
M--none |
S2 |
0.5A,1A,5A |
| B--F6.5 |
5A,10A,15A,25A |
| E--F20 |
S3 |
30A,50A,75A,100A,120A,150A,200A,250A,300A |
SK |
8---110V
9---220V |
S3 |
10A,20A |
* The largest rated input is 20A for 220v power supply
Part Number Example: CE-IJ03-32BS2-O.5/0~5A
Description: 1 element AC Current Transducer, average responding,
Input: 0~5Aac Output: 0~5Vdc, Power source: +12Vdc, Window:
F 6.5mm, Accuracy: 0.5%, Case style:
S2
Diagrams : ( Click one of small diagrams to magnify
it in the right )
| Case Style |
Installation |
Connection |
| |
|
|
| |
|
|
| |
|
|
|
|
|
|
 |
New case style: SK |
|
 |
 |
SK Case Style |
SK Connection |
| Connection diagrams for 220V power supply transducers: |
|
 |
 |
CE-IJ03-*9MS3/CE-IJ03A-*9MS3 |
CE-IJ03-*9BS3/CE-IJ03A-*9BS3 |
Applications for CE-IJ03:
- Multi-point current sensing and control panels
- Monitor lighting elements
- Monitor heating elements
- Remote current sensing
- Monitor motor faults
Applications for CE-IJ03 A:
- Sub-metering Energy Measurement
- Motor Loads
- Remote Monitoring
- Automatic Control Systems
- Loading Shedding
Notice:
- The size of window must be fit for the conducting wire
to pass through. When the rated current £5A,
you can use terminal input.
- All connections of the positive and negative polarities
must be right. The output signal and the power source must
be grounded in common.
The connection diagrams are the top view of the devices. |