| Company
Profile |
| Certificate |
Current Transducer |
Voltage Transducer |
Power Transducer |
Frequency Transducer |
Multi-parameter Transducer |
Other |
|
Select Guide for Transducer with Analog Output |
|
Select Guide for Transducer with Digital Output |
|
Select Guide for Transducer with LED Display |
|
Select Guide for Hall Effect Sensor |
| Software Download |
| Connection of RS-485/232 Converter |
| System Connecting For Transducer with Digital Output |
Application and Programming for Transducer with Digital Output |
Transducer with Analog Output |
Transducer with Digital Output |
Transducer with LED Display |
Hall Effect Sensor |
Vehicle Detector |
| Notices to Users |
| Notices for Installation |
| FAQ For Transducer with RS485 Digital Output |
| FAQ for Transducer with Analog Output |
| Product Knowledge |
| AC 1-element |
| AC 2-element |
| AC 3-element |
| DC |
| AC 1-phase |
| AC 3-phase 3-wire |
| AC 3-phase 4-wire |
| DC |
| AC 1-element |
| AC 3-phase 3-wire |
| AC 3-phase 4-wire |
| AC 1-element |
| AC 3-phase 3-wire |
| AC 3-phase 4-wire |
| AC 3-phase 4-wire, multi-cross |
| Power Factor Transducer |
| Standard Signal Isolator |
| Resistance Transducer |
| Potentiometer Transducer |
| Switch Values Data Logger |
| Ethernet Converter |
| Power Source |
| Vehicle Detector |
| Current Transducer |
| Voltage Transducer |
| Power Transducer |
| Frequency Transducer |
| Other |
| Multi-parameter Transducer |
| Current Transducer |
| Voltage Transducer |
| Multifuction Transducer |
| Current Transducer |
| Voltage Transducer |
| Case A Transducer |
| Case B Transducer |
| Case C Transducer |
| Case D Transducer |
| Case E Transducer |
| Case F Transducer |
| Case LX Transducer |
0-55Hz~5KHz |
|
|
| Resistance/Potentiometer transducer/sensor |
Home >> Quick Search >> Other >> Resistance transducer |
|
|
Specifications: |
Part number |
Operating
Principle |
Isolation |
Response time |
Overload capacity |
Consumption(mW) |
Mount |
CE-R01-5*MS3
CE-W01-5*MS3 |
Electro-
magnetic
induction
|
2500VDC |
=250mS |
1.2 times |
=600 |
Din rail/screw |
|
Part Numbers:
| Series |
Output |
Power supply |
Window opening(mm) |
Case style |
Accuracy |
Input range |
| CE-R01
CE-W01 |
5 - 4~20mA (Iy)* |
2-12V, 3-15V,
4-24V, 9-220V |
M-none |
S3 |
0.5 |
100Ω, 300Ω, 50Ω,
700Ω, 1000Ω |
* The load range:100Ω≤RL≤300Ω,Please contact us while the load is over the range(300Ω<RL≤500Ω)
Part number example:CE-R01-59MS3-0.5/0~300Ω
Description:Resistance input with 2 channel output,Output 4~20mA(2 channel),Power supply 220V,
No aperture,S3 case style,Accuracy 0.5,Input resistance 0~300Ω. |
| |
Connections Diagram |
 |
| |
Case style and Mounting diagram(mm)
Case style is S3, its dimensions: L x W x H: 36 x 83 x 76 mm. Type 35 DIN rail mounting or screw mounting shown below. The spacing between terminals is 5.08 mm. |
 |
| |
Features:
- It produces 4-20mA DC output current proportional to the input resistance.
- 2-channel current output, one connect with the meter, the other is for the PC/PLC. And these signals can keep well after long distances transmit.
- It works with 220V AC/DC power supply. And the power supply is isolated from the input/output terminals.
Application:
- With the resistance type or the potentiometer type sensitive unit coordination, serves as valve position transducer and other resistance-type transducer
Notes:
- The 220V power supply is isolated from the output signal. Don’t power on before make the correct connection.
- If the two-fixed terminal of the input potentiometer were made wrong connection, the output current would become smaller while the active terminal of the potentiometer is moving to resistance increasing side. Just exchange line that wired with the two-fixed terminal to solve this.
- The best load capacity for 2-channel 4-20mA current output is 100~300Ω,please contact us if your load is out of that range.
- If there is a meter is used to test the output of the transducer, please make sure the accuracy of the meter is higher than the transduce
|
| |
|
|