| Product Overview |
Home >> Product Overview |
|
|
| Currant Transducer/Sensor |
| Product |
Description |
Series |
Power Supply |
Rated Current |
Output Signals |
Response Time |
Accuracy |
Operating Temperature |
Window Sizes (mm) |
 |
AC 1-element
Current Transducer |
CE-IJ03 |
24V, 220V |
0-0.5A~300A |
4-20mA, 0-5V |
≤300mS |
0.5% |
0-50℃ |
ø20 |
 |
AC 1-element
Current Transducer |
CE-IJ03 |
12V, 24V |
0-1000A |
4-20mA, 0-5V |
≤300mS |
1.0% |
0-50℃ |
ø36 mm |
 |
AC 1-element
leakage current transducer |
CE-IJ03 |
12V, 24V |
0-0.5mA~100mA |
4-20mA, 0-5V |
≤300mS |
1.0% |
0-50℃ |
ø20mm |
 |
AC 1-element
Current Digital Transducer |
CE-AI12 |
24V, 220V |
0-50A |
RS-485, MODBUS |
100mS |
0.2% |
-10℃ -- +55℃ |
ø6.5 |
 |
AC 2-elements
Current Transducer |
CE-IJ21 |
24V, 220V |
0-0.5A~25A |
4-20mA, 0-5V |
≤300mS |
0.5% |
0-50℃ |
ø6.5 |
 |
AC 2-elements
Current Digital Transducer |
CE-AI22 |
24V, 220V |
0-25A |
RS-485, MODBUS |
100mS |
0.2% |
-10℃ -- +55℃ |
ø6.5 |
 |
AC 3-elements
Current Transducer |
CE-IJ31 |
24V, 220V |
0-0.5~25A |
4-20mA, 0-5V |
≤300mS |
0.5% |
0-50℃ |
ø6.5 |
 |
AC 3-elements
Current Digital Transducer |
CE-AI32 |
24V, 220V |
0-5A |
RS-485, MODBUS |
100mS |
0.2% |
-10℃ -- +55℃ |
ø6.5 |
 |
AC 1-element
Offside
Alarm Current Transducer |
CE-IJ03-J |
24V |
0-1~300A |
Relay contacts |
<200mS |
2.0% |
0-50℃ |
ø6.5 |
 |
AC 1-element 4-wire
Self-power
Current Transducer |
CE-IJ03 |
none |
0-1~200A |
Tracking current/voltage 0-5V |
≤250mS |
1.0% |
0-50℃ |
ø20 |
 |
AC 3-elements Self-power
Current Transducer |
CE-IJ31 |
none |
0-25A |
Tracking current/voltage |
≤15µs |
1.0% |
0-50℃ |
ø6.5 |
 |
AC 1-elements Split Core
Current Transducer |
CE-IJ03 |
24V,
self-power |
0-300A |
4-20mA 0-5V |
≤300mS |
1.0% |
0-50℃ |
ø31 |
 |
AC 1-element
Current Transducer |
CE-DI |
24V, 220V |
600V 5A |
4-20mA, RS485, relay, Led display |
320mS |
0.5% |
-5℃ -- +50℃ |
none |
 |
DC 1-element
Current Transducer |
CE-DZ |
24V, 220V |
600V 5A |
4-20mA, RS485, relay, Led display |
320mS |
0.5% |
-5℃ -- +50℃ |
none |
 |
DC 1-element
Current Digital Transducer |
CE-AZ11 |
24V |
0-5A |
RS-485, MODBUS |
100mS |
0.2% |
-10℃ -- +55℃ |
none |
 |
DC 1-element
Current Transducer |
CE-IZ01 |
24V |
0-20mA~5A |
4-20mA, 0-5V |
≤10mS |
0.2% |
0-50℃ |
none |
 |
DC 1-element
Current Transducer |
CE-IZ04 |
24V |
0-30A~300A |
4-20mA, 0-5V |
≤10mS |
1.0% |
0-50℃ |
ø20 |
 |
DC 1-element
Current Transducer |
CE-IZ06 |
24V |
0-1A~25A |
4-20mA,0-5V |
≤100mS |
1.0% |
0-50℃ |
ø20 |
 |
DC 1-elemen Split Core
Current Transducer |
CE-IZ04 |
24V |
0-300A |
4-20mA
0-5V |
≤200mS |
1.0% |
0-50℃ |
ø31 |
 |
DC 1-phase Case A1
Current Transducer |
CE-IZ04-**A1 |
±12V, ±15V |
0-25~900A |
0-5V |
7µs |
1.0% |
-10°C ~ +80°C |
20*10 |
 |
DC 1-phase Case A2
Current Transducer |
CE-IZ04-**A2 |
±12V, ±15V |
0-30~500A |
0-5V 4-20mA |
7µs |
1.0% |
-10°C ~ +80°C |
ø23 |
 |
DC 1-phase Case A3
Current Transducer |
CE-IZ04-**A3 |
±12V, ±15V |
0-30~500A |
0-5V |
7µs |
1.0% |
-10°C ~ +80°C |
21*10 |
 |
DC 1-phase Case A4
Current Transducer |
CE-IZ04-**A4 |
±12V, ±15V |
0-100~800A |
0-5V 4-20mA |
10µs |
1.0% |
-10°C ~ +80°C |
33*16 |
 |
DC 1-phase Case A5
Current Transducer |
CE-IZ04-**A5 |
±12V, ±15V |
0-50~500A |
0-5V 4-20mA |
7µs |
1.0% |
-10°C ~ +80°C |
33*11 |
 |
DC 1-phase Case A6
Current Transducer |
CE-IZ04-**A6 |
±12V, ±15V |
0-50~400A |
0-5V |
7µs |
1.0% |
-10°C ~ +80°C |
ø16 |
 |
DC 1-phase Case A8
Current Transducer |
CE-IZ04-**A8 |
±12V, ±15V |
0-50~400A |
0-5V |
7µs |
1.0% |
-10°C ~ +80°C |
ø20.4 |
 |
DC 1-phase Case B1
Current Transducer |
CE-IZ04-**B1 |
±12V, ±15V |
0-100~1000A |
0-5V 4-20mA |
10µs |
1.0% |
-10°C ~ +80°C |
51*12 |
 |
DC 1-phase Case B2
Current Transducer |
CE-IZ04-**B2 |
±12V, ±15V |
0-300~1500A |
0-5V 4-20mA |
10µs |
1.0% |
-10°C ~ +80°C |
64*16 |
 |
DC 1-phase Case B3
Current Transducer |
CE-IZ04-**B3 |
±12V, ±15V |
0-500~2500A |
0-5V 4-20mA |
10µs |
1.0% |
-10°C ~ +80°C |
104*22 |
 |
DC 1-phase Case B4
Current Transducer |
CE-IZ04-**B4 |
±12V, ±15V |
0-100~1000A |
0-5V 4-20mA |
10µs |
1.0% |
-10°C ~ +80°C |
52*22 |
 |
DC 1-phase Case B5
Current Transducer |
CE-IZ04-**B5 |
±12V, ±15V |
0-300~2500A |
0-5V 4-20mA |
10µs |
1.0% |
-10°C ~ +80°C |
86*26 |
 |
DC 1-phase Case B6
Current Transducer |
CE-IZ04-**B6 |
±12V, ±15V |
0-300~2500A |
0-5V 4-20mA |
10µs |
1.0% |
-10°C ~ +80°C |
103*36 |
 |
DC 1-phase Case B7
Current Transducer |
CE-IZ04-**B7 |
±12V, ±15V |
0-100~800A |
0-5V 4-20mA |
7µs |
1.0% |
-10°C ~ +80°C |
41*11 |
 |
DC 1-phase Case B8
Current Transducer |
CE-IZ04-**B8 |
±12V, ±15V |
0-300~2500A |
0-5V 4-20mA |
10µs |
1.0% |
-10°C ~ +80°C |
85*27 |
 |
DC 1-phase Case C1
Current Transducer |
CE-IZ04-**C1 |
±12V, ±15V |
0-100~1000A |
0-5V 4-20mA |
10µs |
1.0% |
-10°C ~ +80°C |
ø42 |
 |
DC 1-phase Case C2
Current Transducer |
CE-IZ04-**C2 |
±12V, ±15V |
0-200~1500A |
0-5V 4-20mA |
10µs |
1.0% |
-10°C ~ +80°C |
62*15 |
 |
DC 1-phase Case C3
Current Transducer |
CE-IZ04-**C3 |
±12V, ±15V |
0-300~2500A |
0-5V 4-20mA |
10µs |
1.0% |
-10°C ~ +80°C |
85*15 |
 |
DC 1-phase Case C4
Current Transducer |
CE-IZ04-**C4 |
±12V, ±15V |
0-300~6000A |
0-5V 4-20mA |
10µs |
1.0% |
-10°C ~ +80°C |
125*26 |
 |
DC 1-phase Case C5
Current Transducer |
CE-IZ04-**C5 |
±12V, ±15V |
0-300~6000A |
0-5V 4-20mA |
10µs |
1.0% |
-10°C ~ +80°C |
150*40 |
 |
DC 1-phase Case C6
Current Transducer |
CE-IZ04-**C6 |
±12V, ±15V |
0-200~5000A |
0-5V 4-20mA |
10µs |
1.0% |
-10°C ~ +80°C |
125*15 |
 |
DC 1-phase Case C7
Current Transducer |
CE-IZ04-**C7 |
±12V, ±15V |
0-300~1500A |
0-5V 4-20mA |
7µs |
1.0% |
-10°C ~ +80°C |
51*12 |
DC 1-phase Case C8
Current Transducer |
CE-IZ04-**C8 |
±12V, ±15V |
0-50~1000A |
0-5V 4-20mA |
7µs |
1.0% |
-10°C ~ +80°C |
ø22 |
 |
DC 1-phase Case C9
Current Transducer |
CE-IZ04-**C9 |
±12V, ±15V |
0-50~1000A |
0-5V 4-20mA |
7µs |
1.0% |
-10°C ~ +80°C |
ø35 |
 |
DC 1-phase Case C10
Current Transducer |
CE-IZ04-**C10 |
±12V, ±15V |
0-±500~±5000A |
0-5V 4-20mA |
10µs |
1.0% |
-10°C ~ +80°C |
104*20 |
 |
DC 1-phase Case C11
Current Transducer |
CE-IZ04-**C11 |
±12V, ±15V |
0-4000~10000A |
0-5V 4-20mA |
15µs |
1.0% |
-10°C ~ +80°C |
182*70 |
 |
DC 1-phase Case C12
Current Transducer |
CE-IZ04-**C12 |
±12V, ±15V |
0-100~1000A |
0-5V 4-20mA |
7µs |
1.0% |
-10°C ~ +80°C |
41*11 |
 |
DC 1-phase Case C13
Current Transducer |
CE-IZ04-**C13 |
±12V, ±15V |
0-500~2500A |
0-5V 4-20mA |
10µs |
1.0% |
-10°C ~ +80°C |
85*27 |
 |
DC 1-phase Case C14
Current Transducer |
CE-IZ04-**C14 |
±12V, ±15V |
0-10000~30000A |
0-5V 4-20mA |
15µs |
1.0% |
-10°C ~ +80°C |
210*110 |
 |
DC 1-phase Case D1
Current Transducer |
CE-IZ04-**D1 |
±12V, ±15V |
0-300A |
0-150mA |
1µs |
0.5% |
-10°C ~ +80°C |
ø15 |
 |
DC 1-phase Case D2
Current Transducer |
CE-IZ04-**D2 |
±12V, ±15V |
0-400A |
0-200mA |
1µs |
0.5% |
-10°C ~ +80°C |
ø20 |
 |
DC 1-phase Case D3
Current Transducer |
CE-IZ04-**D3 |
±12V, ±15V |
0-500A |
0-100mA |
1µs |
0.5% |
-10°C ~ +80°C |
ø25 |
 |
DC 1-phase Case D4
Current Transducer |
CE-IZ04-**D4 |
±12V, ±15V |
0-1000A |
0-200mA |
1µs |
0.5% |
-10°C ~ +80°C |
ø40 |
 |
DC 1-phase Case D6
Current Transducer |
CE-IZ04-**D6 |
±12V, ±15V |
0-300A |
0-150mA |
1µs |
0.5% |
-10°C ~ +80°C |
ø20.5 |
 |
DC 1-phase Case D7
Current Transducer |
CE-IZ04-**D7 |
±12V, ±15V |
0-500A |
0-100mA |
1µs |
0.5% |
-10°C ~ +80°C |
ø36.5 |
 |
DC 1-phase Case E1
Current Transducer |
CE-IZ04-**E1 |
±12V, ±15V |
0-100~1200A |
0-5V |
7µs |
1.0% |
-10°C ~ +80°C |
20.5*10.5 |
 |
DC 1-phase Case E2
Current Transducer |
CE-IZ04-**E2 |
±12V, ±15V |
0-10mA~2A |
0-5V |
120mS |
1.0% |
-10°C ~ +80°C |
ø15 |
 |
DC 1-phase Case E3
Current Transducer |
CE-IZ04-**E3 |
±12V, ±15V |
0-50~100A |
0-50mA |
1µs |
0.5% |
-10°C ~ +80°C |
12.7*7 |
 |
DC 1-phase Case E4
Current Transducer |
CE-IZ04-**E4 |
±12V, ±15V |
0-10mA~10A |
0-5V 4-20mA |
120ms |
1.0% |
-10°C ~ +80°C |
ø21 |
 |
DC 1-phase Case E5
Current Transducer |
CE-IZ04-**E5 |
±12V, ±15V |
0-10mA~10A |
0-5V 4-20mA |
120ms |
1.0% |
-10°C ~ +80°C |
ø43 |
 |
DC 1-phase Case E6
Current Transducer |
CE-IZ04-**E6 |
±12V, ±15V |
0-100A~1000A |
0-5V
|
10µs |
1.0% |
-10°C ~ +80°C |
ø60 |
 |
DC 1-phase Case E7
Current Transducer |
CE-IZ04-**E7 |
±12V, ±15V |
0-10mA~2A |
0-5V
|
120ms |
1.0% |
-10°C ~ +80°C |
ø35.5 |
 |
DC 1-phase Case E8
Current Transducer |
CE-IZ04-**E8 |
±12V, ±15V |
0-10mA~2A |
0-5V
|
120ms |
0.5% |
-10°C ~ +80°C |
ø20.5 |
 |
DC 1-phase Case E9
Current Transducer |
CE-IZ04-**E9 |
±12V, ±15V |
0-50A~125A |
0-50mA~125mA |
1µs |
0.5% |
-10°C ~ +80°C |
13.5*10.5 |
 |
DC 1-phase Case LX
Current Transducer |
CE-IZ04-**LX |
±12V, ±15V |
0-50A |
0-4V |
3µs |
1.0% |
-10°C ~ +80°C |
|
| Voltage Transducer/Sensor |
| Product |
Description |
Series |
Power Supply |
Rated Current |
Output Signals |
Response Time |
Accuracy |
Operating Temperature |
Window Sizes (mm) |
 |
AC 1-phase
Voltage Transducer |
CE-VJ03 |
24V, 220V |
1-500V |
4-20mA, 0-5V |
≤400mS |
0.5% |
0-50℃ |
none |
 |
AC 1-phase
Voltage Digital Transducer |
CE-AV12 |
24V,
220V |
0-500V |
RS-485, MODBUS |
100mS |
0.2% |
-10℃ -- +55℃ |
none |
 |
AC 3-phase 3-wire
Voltage Transducer |
CE-VJ31 |
24V, 220V |
1-500V |
4-20mA, 0-5V |
≤400mS |
0.5% |
0-50℃ |
none |
 |
AC 3-phase 3-wire
Voltage Digital Transducer |
CE-AV32 |
24V,
220V |
0-500V |
RS-485, MODBUS |
100mS |
0.2% |
-10℃ -- +55℃ |
none |
 |
AC 3-phase 4-wire
Voltage Transducer |
CE-VJ41 |
24V,
220V |
1-500V |
4-20mA, 0-5V |
≤400mS |
0.5% |
0-50℃ |
none |
 |
AC 3-phase 4-wire
Voltage Digital Transducer |
CE-AV42 |
24V,
220V |
0-500V |
RS-485, MODBUS |
100mS |
0.2% |
-10℃ -- +55℃ |
none |
 |
AC 1-element
Offside
Alarm Voltage Transducer |
CE-VJ03-J |
24V |
10V-500V |
Relay
contacts |
<200mS |
2.0% |
0-50℃ |
none |
 |
AC 1-phase Self-power Voltage Transducer |
CE-VJ03 |
none |
0-600V |
Tracking
current/voltage |
≤15µS |
1.0% |
0-50℃ |
none |
 |
AC 3-phase
4-wire
Self-power
Voltage Transducer |
CE-VJ41 |
none |
0-600V |
Tracking
current/voltage |
≤15µS |
1.0% |
0-50℃ |
none |
 |
AC 1-element
Voltage Transducer |
CE-DV |
24V, 220V |
600V 5A |
4-20mA, RS485, relay, Led display |
320mS |
0.5% |
-5℃ -- +50℃ |
none |
 |
DC 1-phase
Voltage Digital Transducer |
CE-AU11 |
24V |
0-500V |
RS-485, MODBUS |
100mS |
0.2% |
-10℃ -- +55℃ |
none |
 |
DC 1-phase
Voltage Transducer |
CE-VZ01 |
24V,
220V |
10mV-500V |
4-20mA, 0-5V |
≤15mS |
0.5% |
0-50℃ |
none |
 |
DC 1-element
Offside
Alarm Voltage Transducer |
CE-VZ01-J |
24V |
10V-500V |
Relay
contacts |
<50mS |
2.0% |
0-50℃ |
none |
 |
DC 1-element
Voltage Transducer |
CE-DU |
24V, 220V |
600V 5A |
4-20mA, RS485, relay, Led display |
320mS |
0.5% |
-5℃ -- +50℃ |
none |
 |
DC 1-phase Case F8
Voltage Transducer |
CE-VZ04-**F8 |
±12V, ±15V |
0-2500V |
0-40mA |
75µs |
0.5% |
-10°C ~ +80°C |
none |
| Product |
Description |
Series |
Power Supply |
Rated Current |
Output Signals |
Response Time |
Accuracy |
Operating Temperature |
Window Sizes (mm) |
 |
Active
Power Transducer |
CE-P02 |
24V, 220V |
0-500V
5A-300A |
4-20mA, 0-5V |
≤600mS |
0.5% |
0-50℃ |
ø6.5 |
 |
Reactive
Power Transducer |
CE-Q02 |
24V, 220V |
0-500V
5A-300A |
4-20mA, 0-5V |
≤600mS |
05% |
0-50℃ |
ø6.5 |
 |
3-phase 3-wire
Active Power Transducer |
CE-P31 |
24V, 220V |
0-500V
1A-25A |
4-20mA, 0-5V
|
≤600mS |
0.5% |
0-50℃ |
ø6.5 |
 |
3-phase 3-wire
Reactive Power Transducer |
CE-Q31 |
24V, 220V |
0-500V
1A-25A |
4-20mA, 0-5V
|
≤600mS |
05% |
0-50℃ |
ø6.5 |
 |
3-phase 4-wire
Active Power Transducer |
CE-P41 |
24V, 220V |
0-500V
1A-25A |
4-20mA, 0-5V
|
≤600mS |
0.5% |
0-50℃ |
ø6.5 |
 |
3-phase 4-wire
Reactive Power Transducer |
CE-Q41 |
24V, 220V |
0-500V
1A-25A |
4-20mA, 0-5V
|
≤600mS |
0.5% |
0-50℃ |
ø6.5 |
| Frequency Transducer/Sensor |
| Product |
Description |
Series |
Power Supply |
Rated Current |
Output Signals |
Response Time |
Accuracy |
Operating Temperature |
Window Sizes (mm) |
 |
Frequency Transducer |
CE-F01 |
24V,220V |
55Hz-5KHz, 0-500V,
0-250V(F03) |
4-20mA, 0-5V |
≤400mS |
0.5% |
0-50℃ |
none |
 |
Frequency Transducer |
CE-F03 |
24V,220V |
45-65Hz, 0-500V,
0-250V(F03) |
4-20mA, 0-5V |
≤400mS |
0.5% |
0-50℃ |
none |
| Multi-parameter Transducer/Sensor |
| Product |
Description |
Series |
Power Supply |
Rated Current |
Output Signals |
Response Time |
Accuracy |
Operating Temperature |
Window Sizes (mm) |
 |
AC 1-element
Multifunction Transducer |
CE-DJ |
24V, 220V |
500V 5A |
4-20mA, RS485,
relay, Led display |
400mS |
0.5% |
-5℃ - +50℃ |
none |
 |
1-element
Multi-parameter
Digital Transducer |
CE-AJ1* |
24V,
220V
AC/DC |
500V * 50A |
RS-485, MODBUS |
100mS |
0.5% |
-10℃- +55℃ |
ø6.5 |
 |
3-Phase 3-wire
Multi-parameter Digital Transducer |
CE-AJ3* |
24V,
220V
AC/DC |
500V * 50A |
RS-485, MODBUS |
100mS |
0.5% |
-10℃- +55℃ |
ø6.5 |
 |
3-Phase 4-wire
Multi-parameter Digital Transducer |
CE-AJ4* |
24V, 220V
AC/DC |
500V * 50A |
RS-485, MODBUS |
100mS |
0.5% |
-10℃- +55℃ |
ø6.5 |
 |
3-Phase 4-wire
Multi-parameter Digital Transducer |
CE-AJ4*-N2 |
24V, 220V
AC/DC |
500V * 5A |
RS-485,
relay, 4-20mA |
100mS |
0.5% |
-10℃- +55℃ |
none |
 |
S5 Case
Multifunction Digital Transducer |
CE-AJ*-DS5 |
24V 220V AC/DC |
1000V*80A |
RS-485, MODBUS |
100ms |
0.5% |
-10℃-+55℃ |
ø11mm |
 |
1-element DC
multi-parameter digital transducer |
CE-AD11 |
24V |
500V*5A |
RS-485, MODBUS |
100mS |
0.5% |
-10℃ - +55℃ |
none |
 |
1-element DC
Multi-parameter Digital Transducer |
CE-AD12 |
+12V, +24V |
0-5-500A,
0-1000V
|
RS-485,MODBUS |
100mS |
1.0% |
-10℃ -+ 55℃ |
ø20mm |
 |
DC Current Digital
Hall Effect Transducer |
CE-AZ12 |
+12V, +24V |
0~5-100A; 0~±5-±100A |
RS-485,MODBUS |
≤250mS |
1.0% |
-10℃ -+ 55℃ |
ø20mm |
| Product |
Description |
Sereis |
Power Supply |
Rated Current |
Output Signals |
Response Time |
Accuracy |
Operating Temperature |
Window Sizes (mm) |
 |
Power Source |
CE-WYS-1 |
none |
220V |
500mA 24V |
|
|
0-50℃ |
none |
 |
Power Source |
CE-WYS-2 |
none |
220V |
200mA 24V |
|
|
0-50℃ |
none |
 |
Standard Signal Isolator
1-channel output |
CE-IZ07 |
24V |
4-20mA |
0-5V, 4-20mA |
≤150mS |
0.5% |
0-50℃ |
none |
 |
Standard Signal Isolator
2-channel output |
CE-IZ27 |
24V |
4-20mA |
0-5V, 4-20mA |
≤150mS |
0.5% |
0-50℃ |
none |
 |
Resistance Transducer |
CE-R01 |
24V, 220V |
0-1000ohm |
0-5V, 4-20mA |
≤250mS |
0.5% |
0-50℃ |
none |
 |
Potentiometer Transducer |
CE-W01 |
24V, 220V |
0-300-1K |
4-20mA |
≤250mS |
0.5% |
0-50℃ |
none |
 |
1-Phase
Power Factor Transducer |
CE-C02 |
24V, 220V |
500V *25A |
0-5V, 4-20mA |
≤250mS |
0.5% |
0-50℃ |
ø6.5 |
 |
Switch Values Data Logger |
CE-AK10 |
24V |
on-off 8 or 16-channel |
1 or 2 byte |
|
|
-10℃ -- +55℃ |
none |
Vehicle Detector
| Product |
Description |
Series |
Power Supply |
Self tuning Range |
Sensitivity |
Response Time |
Operating Temperature |
 |
Single channel
loop detector |
CE-L02-J9 |
220V |
30—700uH |
0.2%~1.28% |
<100 ms |
-40ºC ~ +70ºC |
 |
Dual channel
loop detector |
CE-L22-J9 |
220V |
20—1000uH |
0.08%~0.32% |
<100 ms |
-40ºC ~ +70ºC |
 |
4-channel
loop detector |
CE-L42-J9 |
220V |
20—1500uH |
0.04%~1.28% |
traffic type(A type)≤30ms,speed measuring type(B type)≤4ms |
-40ºC ~ +70ºC |
 |
8-channel
loop detector |
CE-L82-J9 |
220V |
20—1500uH |
0.05%~0.16% |
Traffic(A type)≤30ms,speed measuring(B type)≤4ms |
-40ºC ~ +70ºC |
|
|
|