Specifications:

Part number

Operating Principle

Isolation

Response time

Overload capacity

Consumption(mW)

Mount

CE-R01-59GS3
CE-W01-59MS3
Electro- magnetic induction 2500VDC =250mS 1.2 times =600 Din rail/screw

SPart Numbers:

Series Output Power supply Window opening(mm) Case style Accuracy Input range
CE-R01 CE-W01 5 - 4~20mA (Iy)* 9-220V M-none S3 0.5 100O, 300O, 50O,
700O, 1000O

* The load range:100Ω≤RL≤300Ω,Please contact us while the load is over the range(300Ω<RL≤500Ω)

Part number example:CE-R01-59MS3-0.5/0~300Ω
Description:Resistance input with 2 channel output,Output 4~20mA(2 channel),Power supply 220V, 
No aperture,S3 case style,Accuracy 0.5,Input resistance 0~300Ω.

 

Connections Diagram

 

Case style and Mounting diagram(mm)

Case style is S3, its dimensions: L x W x H: 36 x 83 x 76 mm. Type 35 DIN rail mounting or screw mounting shown below. The spacing between terminals is 5.08 mm.

 

Features:

  1. It produces 4-20mA DC output current proportional to the input resistance.
  2. 2-channel current output, one connect with the meter, the other is for the PC/PLC. And these signals can keep well after long distances transmit.
  3. It works with 220V AC/DC power supply. And the power supply is isolated from the input/output terminals.

Application:

  • With the resistance type or the potentiometer type sensitive unit coordination, serves as valve position transducer and other resistance-type transducer

Notes:

  1. The 220V power supply is isolated from the output signal. Don’t power on before make the correct connection.
  2. If the two-fixed terminal of the input potentiometer were made wrong connection, the output current would become smaller while the active terminal of the potentiometer is moving to resistance increasing side. Just exchange line that wired with the two-fixed terminal to solve this.
  3. The best load capacity for 2-channel 4-20mA current output is 100~300Ω,please contact us if your load is out of that range.
  4. If there is a meter is used to test the output of the transducer, please make sure the accuracy of the meter is higher than the transduce
 
2006-2009 © Copyright by Shenzhen Sensor Electronic Technology Co.,Ltd.