Transducer with analog output Transducer with led display Transducer with RS485 digital output Hall Effect Current Sensor

Hall Effect Current Sensor Home >> Hall Effect Current Sensor
Product Description Series Power Supply Rated Current Output Signals Response Time Accuracy Operating Temperature Window Sizes (mm)
DC 1-phase Case A1
Current Transducer
CE-IZ04-**A1 ±12V,±15V 0-25~900A 0-5V 7µs 1.0% -10°C ~ +80°C 20*10
DC 1-phase Case A2
Current Transducer
CE-IZ04-**A2 ±12V,±15V 0-30~500A 0-5V 4-20mA 7µs 1.0% -10°C ~ +80°C ø23
DC 1-phase Case A3
Current Transducer
CE-IZ04-**A3 ±12V,±15V 0-30~500A 0-5V 7µs 1.0% -10°C ~ +80°C 21*10
DC 1-phase Case A4
Current Transducer
CE-IZ04-**A4 ±12V,±15V 0-100~800A 0-5V 4-20mA 10µs 1.0% -10°C ~ +80°C 33*16
DC 1-phase Case A5
Current Transducer
CE-IZ04-**A5 ±12V,±15V 0-50~500A 0-5V 4-20mA 7µs 1.0% -10°C ~ +80°C 33*11
DC 1-phase Case A6
Current Transducer
CE-IZ04-**A6 ±12V,±15V 0-50~400A 0-5V 7µs 1.0% -10°C ~ +80°C ø16
DC 1-phase Case A8
Current Transducer
CE-IZ04-**A8 ±12V,±15V 0-50~400A 0-5V 7µs 1.0% -10°C ~ +80°C ø20.4
DC 1-phase Case B1
Current Transducer
CE-IZ04-**B1 ±12V,±15V 0-100~1000A 0-5V 4-20mA 10µs 1.0% -10°C ~ +80°C 51*12
DC 1-phase Case B2
Current Transducer
CE-IZ04-**B2 ±12V,±15V 0-300~1500A 0-5V 4-20mA 10µs 1.0% -10°C ~ +80°C 64*16
DC 1-phase Case B3
Current Transducer
CE-IZ04-**B3 ±12V,±15V 0-500~2500A 0-5V 4-20mA 10µs 1.0% -10°C ~ +80°C 104*22
DC 1-phase Case B4
Current Transducer
CE-IZ04-**B4 ±12V,±15V 0-100~1000A 0-5V 4-20mA 10µs 1.0% -10°C ~ +80°C 52*22
DC 1-phase Case B5
Current Transducer
CE-IZ04-**B5 ±12V,±15V 0-300~2500A 0-5V 4-20mA 10µs 1.0% -10°C ~ +80°C 86*26
DC 1-phase Case B6
Current Transducer
CE-IZ04-**B6 ±12V,±15V 0-300~2500A 0-5V 4-20mA 10µs 1.0% -10°C ~ +80°C 103*36
DC 1-phase Case B7
Current Transducer
CE-IZ04-**B7 ±12V,±15V 0-100~800A 0-5V 4-20mA 7µs 1.0% -10°C ~ +80°C 41*11
DC 1-phase Case B8
Current Transducer
CE-IZ04-**B8 ±12V,±15V 0-300~2500A 0-5V 4-20mA 10µs 1.0% -10°C ~ +80°C 85*27
DC 1-phase Case C1
Current Transducer
CE-IZ04-**C1 ±12V,±15V 0-100~1000A 0-5V 4-20mA 10µs 1.0% -10°C ~ +80°C ø42
DC 1-phase Case C2
Current Transducer
CE-IZ04-**C2 ±12V,±15V 0-200~1500A 0-5V 4-20mA 10µs 1.0% -10°C ~ +80°C 62*15
DC 1-phase Case C3
Current Transducer
CE-IZ04-**C3 ±12V,±15V 0-300~2500A 0-5V 4-20mA 10µs 1.0% -10°C ~ +80°C 85*15
DC 1-phase Case C4
Current Transducer
CE-IZ04-**C4 ±12V,±15V 0-300~6000A 0-5V 4-20mA 10µs 1.0% -10°C ~ +80°C 125*26
DC 1-phase Case C5
Current Transducer
CE-IZ04-**C5 ±12V,±15V 0-300~6000A 0-5V 4-20mA 10µs 1.0% -10°C ~ +80°C 150*40
DC 1-phase Case C6
Current Transducer
CE-IZ04-**C6 ±12V,±15V 0-200~5000A 0-5V 4-20mA 10µs 1.0% -10°C ~ +80°C 125*15
DC 1-phase Case C7
Current Transducer
CE-IZ04-**C7 ±12V,±15V 0-300~1500A 0-5V 4-20mA 7µs 1.0% -10°C ~ +80°C 51*12
DC 1-phase Case C8
Current Transducer
CE-IZ04-**C8 ±12V,±15V 0-50~1000A 0-5V 4-20mA 7µs 1.0% -10°C ~ +80°C ø22
DC 1-phase Case C9
Current Transducer
CE-IZ04-**C9 ±12V,±15V 0-50~1000A 0-5V 4-20mA 7µs 1.0% -10°C ~ +80°C ø35
DC 1-phase Case C10
Current Transducer
CE-IZ04-**C10 ±12V,±15V 0-±500~±5000A 0-5V 4-20mA 10µs 1.0% -10°C ~ +80°C 104*20
DC 1-phase Case C11
Current Transducer
CE-IZ04-**C11 ±12V,±15V 0-4000~10000A 0-5V 4-20mA 15µs 1.0% -10°C ~ +80°C 182*70
DC 1-phase Case C12
Current Transducer
CE-IZ04-**C12 ±12V,±15V 0-100~1000A 0-5V 4-20mA 7µs 1.0% -10°C ~ +80°C 41*11
DC 1-phase Case C13
Current Transducer
CE-IZ04-**C13 ±12V,±15V 0-500~2500A 0-5V 4-20mA 10µs 1.0% -10°C ~ +80°C 85*27
DC 1-phase Case C14
Current Transducer
CE-IZ04-**C14 ±12V,±15V 0-10000~30000A 0-5V 4-20mA 15µs 1.0% -10°C ~ +80°C 210*110
DC 1-phase Case D1 
Current Transducer
CE-IZ04-**D1 ±12V,±15V 0-300A 0-150mA 1µs 0.5% -10°C ~ +80°C ø15
DC 1-phase Case D2 
Current Transducer
CE-IZ04-**D2 ±12V,±15V 0-400A 0-200mA 1µs 0.5% -10°C ~ +80°C ø20
DC 1-phase Case D3 
Current Transducer
CE-IZ04-**D3 ±12V,±15V 0-500A 0-100mA 1µs 0.5% -10°C ~ +80°C ø25
DC 1-phase Case D4 
Current Transducer
CE-IZ04-**D4 ±12V,±15V 0-1000A 0-200mA 1µs 0.5% -10°C ~ +80°C ø40
DC 1-phase Case D6 
Current Transducer
CE-IZ04-**D6 ±12V,±15V 0-300A 0-150mA 1µs 0.5% -10°C ~ +80°C ø20.5
DC 1-phase Case D7 
Current Transducer
CE-IZ04-**D7 ±12V,±15V 0-500A 0-100mA 1µs 0.5% -10°C ~ +80°C ø36.5
DC 1-phase Case E1  
Current Transducer
CE-IZ04-**E1 ±12V,±15V 0-100~1200A 0-5V 7µs 1.0% -10°C ~ +80°C 20.5*10.5
DC 1-phase Case E2
Current Transducer
CE-IZ04-**E2 ±12V,±15V 0-10mA~2A 0-5V 120mS 1.0% -10°C ~ +80°C ø15
DC 1-phase Case E3  
Current Transducer
CE-IZ04-**E3 ±12V,±15V 0-50~100A 0-50mA 1µs 0.5% -10°C ~ +80°C 12.7*7
DC 1-phase Case E4  
Current Transducer
CE-IZ04-**E4 ±12V,±15V 0-10mA~10A 0-5V 4-20mA 120ms 1.0% -10°C ~ +80°C ø21
DC 1-phase Case E5  
Current Transducer
CE-IZ04-**E5 ±12V,±15V 0-10mA~10A 0-5V 4-20mA 120ms 1.0% -10°C ~ +80°C ø43
DC 1-phase Case E6  
Current Transducer
CE-IZ04-**E6 ±12V,±15V 0-100A~1000A 0-5V
10µs 1.0% -10°C ~ +80°C ø60
DC 1-phase Case E7  
Current Transducer
CE-IZ04-**E7 ±12V,±15V 0-10mA~2A 0-5V
120ms 1.0% -10°C ~ +80°C ø35.5
DC 1-phase Case E8
Current Transducer
CE-IZ04-**E8 ±12V,±15V 0-10mA~2A 0-5V
120ms 0.5% -10°C ~ +80°C ø20.5
DC 1-phase Case E9
Current Transducer
CE-IZ04-**E9 ±12V,±15V 0-50A~125A 0-50mA~125mA 1µs 0.5% -10°C ~ +80°C 13.5*10.5
DC 1-phase Case LX 
Current Transducer
CE-IZ04-**LX ±12V,±15V 0-50A 0-4V 3µs 1.0% -10°C ~ +80°C current sensor A, current sensor B, current sensor C, current sensor D, current sensor E, current sensor F, current sensor 1000A, current sensor 2000A, current sensor 3000A, current sensor 4000A, current sensor 5000A, current sensor 6000A, current sensor 7000A, current sensor 8000A, current sensor 9000A, hall effect sensor, hall sensor, hall-effect sensor, hall device, hall devices, hall effect
DC 1-phase Case F8
Voltage Transducer
CE-VZ04-**F8 ±12V, ±15V 0-2500V 0-40mA 75µs 0.5% -10°C ~ +80°C none
2006-2009 © Copyright by Shenzhen Sensor Electronic Technology Co.,Ltd.
Address: unit 4-9; Floor 4; Shenzheng Building; 42 MeiLin Road; Shenzhen City; China
Tel: 0086 755 8376 6915 Fax: 0086 755 8376 3161
GuangDong,China ICP NO:05081717