The troubleshooting of Analog Transducer
   
 

The direction of the products' input

Case style

Direction of the input

Part number

Remark

ES3 (1 phase)

CE-IZ04 (DC current)
CE-IZ06 (DC current)

The side which has a
symbol "(+)" is the current input

BS3 (1 phase)

CE-P02 (1 phase active)
CE-Q02 (1 phase reactive)
CE-C02 (power factor)
CE-AJ11 (1 phase digital output)
CE-AJ12 (1 phase digital output)

The side which has a connection
diagram is the current input

BS3 (2 phase)

CE-P31 (3-phase 3-wire active)
CE-Q31 (3-phase 3-wire reactive)
CE-AJ31 (3-phase 3-wire digital output)
CE-AJ32 (3-phase 3-wire digital output)

The side which has a
label is the current output

BS3 (3 phase)

CE-P41 (3-phase 4-wire active)
CE-Q41 (3-phase 4-wire reactive)
CE-AJ41 (3-phase 4-wire digital output)
CE-AJ42 (3-phase 4-wire digital output)

The side which has a
label is the current output

BS3 (1 phase)

CE-IZ06 (DC current)

The side which has a
symbol "(+)" is the current input.
It is the same with the DC input

There is no output signal when input signal is applied and power is on

  • Cut off power supply and check if all connections are correct, the terminals and wires are connected properly, the screws of
    terminal are tightened securely and reliably.
  • Check if the power supply and input meets the requirements shown on the label, and the polarity of DC input is connected correctly.
  • Check whether the load resistance mentioned in 2.4 above is satisfied.
  • Make sure abovementioned everything is OK, then power on. If the problem still exists. Please contact with the company.

There is an unusual output or an output with bad accuracy.

  • Check and correct everything according to that mentioned in 3.1 above.
  • Use a digital multimeter whose accuracy is better than the transducer to measure the voltage of power supply and input to see if
    the values meet the requirements shown on the label.
  • For CE-P, CE-Q power transducers, wrong connection of their input phase lines or wrong phase line sequence will cause
    unusual output
  • Check the environment and associated application to see if it meets the requirements stipulated in 1.2, 1.3, 2.4 and 2.6 above.
  • Make sure abovementioned everything is OK, then power on. If the problem still exists. Please contact with the company.
The output signal jumps or drifts up and down quickly
  • Check and correct everything according to that mentioned in 3.1 above.
  • Check the voltage and ripple of power supply.
  • Check the input signal to see whether it jumps, or its amplitude is outside the measure range of the transducer.
  • Check the environment and associated application to see whether it meets the requirements stipulated in 1.2, 1.3, 2.4 and
    2.6 above or not..
  • Make sure abovementioned everything is OK, then power on. If the problem still exists. Please contact with the company

The product has no output when it works for some time.

  • Use the handle of a screwdriver to flip the encloser of the transducer gently to see if there is poor connection or less screwed.
  • Check the voltage of power supply whether is correct or not and input whether meets the requirement shown on the label or not.
  • Check the output load to see whether it meats the requirements stipulated in 2.4 above or not.
  • Make sure abovementioned everything is OK, then power on. If the problem still exists. Please contact with the company.

The product with S case style and CE-VZ02. There is no output signal when input signal is applied and power is on

  • Cut off power supply and check if all connections are correct, the terminals and wires are connected properly, the screws of
    terminal are tightened securely and reliably.

1: Positive input 5: Positive power supply

3: Negative input 6: Negative power supply

8: Signal output

Annotations: All the sequence number please refer to <Notice to user>

 
2006-2009 © Copyright by Shenzhen Sensor Electronic Technology Co.,Ltd.
Address: unit 4-9; Floor 4; Shenzheng Building; 42 MeiLin Road; Shenzhen City; China
Tel: 0086 755 8376 6915 Fax: 0086 755 8376 3161
GuangDong,China ICP NO:05081717