| Company
Profile |
| Certificate |
| News |
Current Transducer |
Voltage Transducer |
Power Transducer |
Frequency Transducer |
Multi-parameter Transducer |
Other |
|
Select Guide for Transducer with Analog Output |
|
Select Guide for Transducer with Digital Output |
|
Select Guide for Transducer with LED Display |
|
Select Guide for Hall Effect Sensor |
| Software Download |
| Connection of RS-485/232 Converter |
| System Connecting For Transducer with Digital Output |
Application and Programming for Transducer with Digital Output |
Transducer with Analog Output |
Transducer with Digital Output |
Transducer with LED Display |
Hall Effect Sensor |
Vehicle Detector |
| Notices to Users |
| Notices for Installation |
| FAQ For Transducer with RS485 Digital Output |
| FAQ for Transducer with Analog Output |
| Product Knowledge |
| AC 1-element |
| AC 2-element |
| AC 3-element |
| DC |
| AC 1-phase |
| AC 3-phase 3-wire |
| AC 3-phase 4-wire |
| DC |
| AC 1-element |
| AC 3-phase 3-wire |
| AC 3-phase 4-wire |
| AC 1-element |
| AC 3-phase 3-wire |
| AC 3-phase 4-wire |
| AC 3-phase 4-wire, multi-cross |
| Power Factor Transducer |
| Standard Signal Isolator |
| Resistance Transducer |
| Potentiometer Transducer |
| Switch Values Data Logger |
| Ethernet Converter |
| Power Source |
| Vehicle Detector |
| Current Transducer |
| Voltage Transducer |
| Power Transducer |
| Frequency Transducer |
| Other |
| Multi-parameter Transducer |
| Current Transducer |
| Voltage Transducer |
| Multifuction Transducer |
| Current Transducer |
| Voltage Transducer |
| Case A Transducer |
| Case B Transducer |
| Case C Transducer |
| Case D Transducer |
| Case E Transducer |
| Case F Transducer |
| Case LX Transducer |
0-55Hz~5KHz |
|
|
| CE-NM20/30/40 Power Source |
Home >> Current Transducer >> Power |
|
|
| Diagram: |
Features: |
|
- Input range:300-900V DC
- With overload and short circuit protection
- High efficient
- 3000VAC isolation;
- Low ripple/noise
- Rate power up to 35W;
- Wide operation temp. -40~+85℃
|
Special for PV, wind system |
| |
| Series |
Input range(Vdc) |
Output |
Vo1 ripple/noise (mV) |
Efficient(TYP) |
| Vo(V) |
Io(A) |
CAP load limit (ohm) |
| NM20-600S05 |
600(300-900) |
5.0 |
4 |
1000 |
100 |
76 |
| NM20-600S12 |
600(300-900) |
12.1 |
1.66 |
470 |
100 |
80 |
| NM20-600S24 |
600(300-900) |
24.0 |
0.833 |
100 |
100 |
81 |
| |
| NM20-600S05 |
600(300-900) |
5.0 |
6 |
1000 |
100 |
76 |
| NM20-600S12 |
600(300-900) |
12.1 |
2.5 |
470 |
100 |
81 |
| NM20-600S24 |
600(300-900) |
24.0 |
1.25 |
100 |
100 |
82 |
| |
| NM20-600S05 |
600(300-900) |
5.0 |
7 |
1000 |
100 |
76 |
| NM20-600S12 |
600(300-900) |
12.1 |
3.33 |
470 |
100 |
81 |
| NM20-600S24 |
600(300-900) |
24.0 |
1.66 |
100 |
100 |
83 |
|
| Input range |
300 ~ 900VDC (220 ~ 640VAC) |
| Input Frequency |
0 ~ 63Hz |
| Input current(typical) |
NM20-600SXX |
44mA/600Vdc 75mA/420VAC |
| NM30-600SXX |
66mA/600Vdc 115mA/420VAC |
| NM40-600SXX |
83mA/600Vdc 146mA/420VAC |
| Input surge current (typical) |
30A/600VDC 30A/420VAC |
| Leakage current(typical) |
<1mA at 230VAC/50Hz |
| Input filter type |
LC ∏ |
| Response time |
≤10ms |
| Accuracy |
Vo ±2.0%, @25℃ |
| Linearity |
±1.0% |
| Load capacity |
(Vo)±1.0% ,10%~100% |
| Overcurrent portection |
110%, Self recover |
| Response |
25% of standard load △Vo1/△t 200us |
| Switch frequency |
100kHz (typical) |
| Temperature |
Operation temp |
-40 ~ +85 ℃ (reference temp.&load relationship graphs.) |
| Storage temp. |
-40 ~ +85, 10 ~ 95% RH |
| Drift |
0.03%/ (0~ 50℃) |
| Temp. of outside case |
85℃ max |
| Humidity |
85% .RH max |
| The tolerance of shake |
10~500Hz,2G10min./1cycle, 60min.each along X,Y,Z axes |
| Isolation |
Isolation Voltage |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| Isolation resistance |
I/P-O/P,I/P-FG,O/P-FG:>100M Ohms/500VDC 25? 70% RH |
| MTBF |
1000K hrs min. MIL-HDBK-217F(25) |
| Cool method |
Nature |
| Dimensions |
129*99*38mm (L*W*H) |
| Case |
Aluminum |
| Weight |
150g |
| Remark |
1. Test condition: TA=25?, humidity<75%, 600Vdc input with standard load
2. Ripple and noise tested with 300mm twist wires,and there are 0.1uF &47uF in parallel connection at the terminals
3. EMS data needs to consider the devices connected with this power source |
|
|
|
|