Split Core AC Current Transducer
Overview: This split core 1 element AC current transducer uses plug mode. It's easy to measure the AC current and output 2-wire 4-20mA DC current which is isolated with input. It is featured in good linearity, high accuracy which is up to class 0.5, low drift, and easy installation and so on. It can be applied in communication, railway, industry control etc.
| |
Series |
Operating Principle |
Isolation Voltage |
Response Time |
Overload Capacity |
Mounting |
| CE-IJ03 |
Electro-magnetic induction |
≤2500VDC |
≤300mS |
20 times or <5/ sec at 500A |
Din rail/Screw |
|
|
| |
| Part numbers: |
| |
Series |
Output |
Power Supply |
Window(mm) |
Case Style |
Accuracy |
Rated Input |
| CE-IJ03 |
7:4-20mA (2-wire,loop powered connection) |
4:24V |
F:ф29 |
S6 |
0.5
1.0
|
0~10A~500A AC |
|
|
| Part Number Example: CE-IJ03-74FS6-1.0/0~50A |
| |
| Description: Spilt core single-phase AC current transducer,Output:4-20mA loop powered, power supply:+24V,,Aperture: ф29mm,Case style:S6,Accuracy:1.0,Input current:0-50A. |
| |
| Connections Diagram : |
| |
 |
| |
| Case Style Dimensions : |
 |
 |
| L*W*H:83*37*87mm |
| |
 |
| 1) Notice: |
| 1. As the fig. shown, if you want to close the split core, put the top part and lower part in a line, then press to the bottom. If you want to open, hold the top part and upward pull. |
| 2) |
| 2. The conductor carrying the input current should pass through the center of the aperture as perpendicularly as possible. |
| 3. Make sure the polarities are in right connection, The output and the power supply must be common grounded. |
| 4. If there is a meter is used to test the output of the transducer, please make sure the accuracy of the meter is higher than the transducer. |
|