Features:
- DC Multi-parameter monitoring, U, I, P, KWH
- Various measure range for option:
Current: 5A, 10A, 20A, up to 500A
Voltage:300V,500V, 750V, up to 1000V
- Isolated Rs485 output,,up to 256pcs sensors available in the network with a repeater
- Work with wide range power source, +9Vdc~+55Vdc
- Bi-diretion detect for U,I,P, KWH
- Energy data power failure protection
- High stability, 2KV surge protection on input, power supply and output interface
- Wireless with Modbus on Zigbee if required
|
| |
| Application |
 |
 |
● Solar string monitor |
● Wind system control
|
| |
|
| |
|
 |
 |
|
|
|
Part Number
CE-AD12B-*4ES5-1.0/U*I |
| Code option for *: |
1.ASCII code ,RS485
2.ASCII code , RS232
3.Modbus protocol,RS485
4.Modbus protocol,RS232 |
| Rated input range : |
U: 0~1000V
I: 0~5A~500A |
Specification:
1. Accuracy 0.2,1.0; 0.2 for voltage,current and power 1.0
2. Baud rate 19.2K, 9600(default), 4800, 2400, 1200 bps
3. Communication RS-485 twisted pair line or RS232
4. Communication distance 1200m(RS-485)
5. Max. number of nodes 64 node
6. A/D speed 100mS
7. Working temperature -20centigrade ~ +60 centigrade
8. Isolation Input/output: 2500V DC for 1 min
9. Overload 2 x Voltage span for 1 sec. 10 times with interval of 10 sec.
10. MTBF >30000Hour
11. Auxiliary power supply +9~+55Vdc
Connection:

Dimensions
L*W*H=86.5mm*70mm*74mm
Window aperture: 20mm diam.(For current hole-thru. Input) |
Download
1. MODBUS Protocol
2. ASCII Format
|